Floating switch SI/FS/NL/1/K/RN Variante 0
|
|
|
|
![]() |
|
For use in intrinsically safe circuits in mines susceptible to firedamp or in potentially explosive atmospheres in categories zone 1 or 2. EC type examination certificate: INERIS 03ATEX0149 Application in liquids with a specific density between d = 1.05 and d =0.95 g/cm³ |
|
| Brochure Mercury-free floating switches and immersion probes [PDF] | |
|
|
|
| Contact |
ball-operated microswitch, potential-free changeover contact |
| Float material | PP |
| Seal material | FPM |
| Float protection class | IP 68 |
| Float diameter | 74 mm |
| Float length | 130 mm |
| Mounting orientation | vertical |
| Mounting | from the top |
| Connecting cable |
grey A05 RN-F cable, 3 x 0,75 |
| Application range of
the connecting cable |
for water, used water, slightly aggressive liquids |
Connecting cable length |
1 metre, other cable lengths on request. When ordering, please always state the desired cable length and cable type. |
| Temperature application range |
0° C to + 60° C |
| Max. immersion depth of the float |
max. 10 metres head of water at + 20° C |
| Documents for application in explosive atmospheres |
EC type examination certificate [PDF] EC Declaration of Conformity [PDF] Installation, operating and maintenance instructions [to the language selection] |
|
|
|
This unit has to be connected to a certified intrinsically safe circuit. We can supply appropriate protection relays on request. Recommended application via Jola protection relay KR 5/Ex |
|
This floating switch is designed for mounting from the top. This is fitted with a built-in weight for fixing the switching point at the desired height; this renders additional fastening of the switch at the height of the switching point unnecessary. This weight is dimensioned in such a way that the switch tilts around its own axis when the liquid level rises and then follows the rising liquid level. This tilting action of the float activates the switching process. This unit is not suitable for use in turbulent liquids (e.g. in stirrer tanks).
|
|
| Measure drawing |
| Function sketch |
| Function sketch 2 |
| Basic circuit |
| Top |