Jola Spezialschalter K. Mattil
& Co. KG
Klostergartenstraße 11-20 D-67466 Lambrecht Phone: +49 63 25 / 188-01 |
Cable electrode EL/Z6V2/KE/40/2/PP/ED/1/Ex-1G
|
|
|
|
|
|
![]() | |
| Picture 2 | |
| Picture 3 | |
For use in intrinsically safe circuits in potentially explosive atmospheres in categories Zone 1 or 2. EC type examination certificate: INERIS 03ATEX0152 For signalling the presence of an electrically conductive liquid caused, for example by burst pipes. Cable electrodes can, for example, be used on normally dry floors or false ceilings or in normally dry pipeline and cable ducts. Cable electrodes can also be used alongside pipes or in double-pipe systems. If the two electrode cables of a cable electrode come into contact with an electrically conductive liquid (e.g. water, acid etc.), an electrical contact is made and an alarm signal given. Sensor cables: 2 cables made of stainless steel rope 316 or 316 Ti, each 3 mm in dia., each covered by a halogen-free protective polyester sheath; length: 2 metres each, longer on request |
|
| |
|
| Control electrode | 1 |
| Earth electrode | 1 |
| Electrical connection / Connecting cable |
blue PVC cable, 2 x 0,75 |
| Cable length |
2 metres, longer cable on request; halogen-free connecting cable on request |
| Mounting orientation | horizontal |
| Temperature resistance |
- 20° C to + 60° C |
| Pressure resistance |
for pressureless applications only, for use under atmospheric conditions only |
| Documents for application in explosive atmospheres |
EC type examination certificate [PDF] EC Declaration of Conformity [PDF] Installation, operating and maintenance instructions [to the language selection] |
| |
|
Supplied mounting accessories: 4 sensor cable spacers made of PP per metre of sensor cable |
|
The cable electrode is fitted with two separate electrodes in the form of two sensor cables: 1 control electrode and 1 earth electrode. As soon as a trace of a conductive liquid creates a conductive path between the two sensor cables, a control current flows from the corresponding electrode relay. The latter is then energised and a contact made. Each of the two sensor cables consists of a stainless steel rope core and a protective sheath made of polyester. This protective sheath is designed to prevent contact of the stainless steel ropes with one another or with an electrically conductive surface (e.g. steel tube, steel pipe etc.) and thus to avoid false alarms, whilst allowing leakage liquid to penetrate through to the stainless steel ropes. The two sensor cables of the cable electrode must be mounted parallel to one another at a distance of approx. 2 cm using the sensor cable spacers, as a greater or lesser spacing affects the response level of the system in the event of leakage. The cable electrode should be connected to electrode relay Leckstar 101/Ex |
|
| Top |