Electrode relay
NR 3 A |
|
![]() |
|
Alternative supply voltages
AC versions : terminals 10 + 12;
DC versions :
terminal 10 = -
terminal 12 = + :
- AC 230 V (delivered if no other supply voltage is specified in the order) or
- AC 240 V or
- AC 115 V or
- AC 24 V
- DC 24 V or
- DC 12 V (in these two cases, the unit must only be connected to a low safety voltage
which corresponds to the safety regulations relating to the application)
- further supply voltages on request
Power input: approx. 3 VA
Electrode circuit (terminals 4, 6): 2 terminals (safety extra low voltage SELV) acting on 1 relay
- no-load voltage: 9 V eff AC square wave voltage 10 Hz (safety extra low voltage SELV)
- short-circuit current: max. 0.5 mA eff
Controlled circuit (terminals 7,8,9): 1 single-pole potential-free changeover contact
Switching status indicators:
- 1 green LED lights when relay is energised
- 1 red LED lights when relay is not energised |
|
| |
|
| Mounting orientation | any |
| Temperature resistance |
- 20° C to + 60° C |
| Power input | approx. 3 VA |
| Response sensitivity | approx. 30 kOhm |
| Response sensitivity (electric conductance) | approx. 33 µS |
| Switching voltage AC max. | 250 V |
| Switching current AC max. | 4 A |
| Switching capacity AC max. | 500 VA |
| Housing |
insulating material, 75 x 22.5 x 100 mm Connection: terminals on top of housing Protection class: IP 20 Mounting: clip attachment for U-bar to DIN 46 277 and DIN EN 50 022 |
| Documents | Installation, operating and maintenance instructions [PDF] | |
Electrode relay for U-bar mounting, with connection terminals on top of housing and with 2 built-in LEDs for signalling the respective switching status. Max. cable length between electrode relay and electrodes: 1,000 m. EMC: for interference emission in accordance with the appliance-specific requirements for households, business and commerce as well as small companies, and for interference immunity in accordance with the appliance-specific requirements for industrial companies. |
|
| Measure drawing |
| Top |