Jola Spezialschalter K. Mattil
& Co. KG
Klostergartenstraße 11-20 D-67466 Lambrecht Phone: +49 63 25 / 188-01 |
Suspension electrode EL/Z6V2/EHW/NL1/20/2/PP/HC/1/Ex-1G
|
|
|
|
|
|
![]() | |
| Picture 2 | |
For use in intrinsically safe circuits in potentially explosive atmospheres in categories Zone 1 or 2. EC type examination certificate: INERIS 03ATEX0152 For signalling the presence of an electrically conductive liquid caused, for example by burst pipes. If the two electrode rods of a suspension come into contact with an electrically conductive liquid (e.g. water, acid etc.), an electrical contact is made and an alarm signal given. Available electrode rods: - stainless steel 316 Ti - Hastelloy C - Hastelloy B |
|
| |
|
| Control electrode | 1 |
| Earth electrode | 1 |
| Electrode rod material | Hastelloy C |
| Diameter of the electrode rods | 3 mm |
| Electrical connection / Connecting cable |
white PTFE cable, 2 x 0,75 |
| Cable length |
2 metres, longer cable on request |
| Mounting orientation | vertical |
| Housing |
PP, 20 mm dia. x approx. 80 mm high |
| Temperature resistance |
- 20° C to + 80° C |
| Pressure resistance |
for pressureless applications only, for use under atmospheric conditions only |
| Documents for application in explosive atmospheres |
EC type examination certificate [PDF] EC Declaration of Conformity [PDF] Installation, operating and maintenance instructions [to the language selection] |
| |
|
Available connecting cable: - PVC connecting cable or - CM connecting cable or - PTFE connecting cable Version with electrode rods made of: - stainless steel 316 Ti - Hastelloy C or - Hastelloy B and/or with housing made of PVDF or PTFE on request. Mounting accessories: Stuffing glands,and flange with stuffing glands on request |
|
The suspension electrode is fitted with two separate electrodes in the form of two electrode rods: 1 control electrode and 1 earth electrode. As soon as a trace of a conductive liquid creates a conductive path between the two electrode rods, a control current flows from the corresponding electrode relay. The latter is then energised and a contact made. The suspension electrode should be connected to electrode relay Leckstar 101/Ex |
|
| Measure drawing |
| Top |