Jola Spezialschalter K. Mattil
& Co. KG
Klostergartenstraße 11-20 D-67466 Lambrecht Phone: +49 63 25 / 188-01 |
Liquid level indicator
TSQ 4-20/EW/E 5/7,5
|
|
![]() |
|
Consisting of - sensor: Switchable resistances activated by float via reed contacts. - transmitter: A 2-wire module in the terminal box of the liquid level indicator converts the resistance values into a load-independent current signal 4 ... 20 mA. Float suitable for use in liquids with a specific gravity >=0.7 g/cm³ |
|
| Brochure Continuous liquid level measuring with liquid level transmitter TSQ 4-20/… and TSK 4-20/… [PDF] | |
| |
|
| Sensor Probe tube material |
stainless steel 316 Ti |
| Probe tube diameter max. | 20 mm |
| Probe tube length max. | 1,500 mm |
| Screw-in nippel material | stainless steel 316 Ti |
| Screw-in nippel dimension | G1 |
| Float material | stainless steel 316 Ti |
| Float form | ball float |
| Float diameter | 97 mm |
| Terminal box |
A 307 made of PP, 120 x 80 x 55 mm, protection class IP 65 |
| Mounting orientation | vertical |
| Mounting | from the top |
| Temperature application range |
- 20° C to + 80° C |
| Pressure resistance |
max. 12 bar at + 20° C
|
| Measuring principle |
the magnet of the float activates switchable series-connected resistances via reed contacts. This provides a quasi-continuous height-proportional measuring signal Measuring precision: 7.5 mm distance between 2 reed contacts |
| Transmitter |
Measuring electronics: 2 wires (independent of polarity) Setting possibility: 0% value not adjustable, 100 % value adjustable via a potentiometer Power supply: DC 15 - 30 V (independent of polarity) Measuring signal: 4 ... 20 mA Admiss. load in the current loop: max. 200 ohm at 15 V; max. 900 ohm at 30 V Connecting terminals: for max. 2.5 mm² solid cable or max. 1.5 mm² flexible cable |
| |
|
Probe tube length: according to customer specification taking into account the probe tube length. Screw-in nipple: on request G1½ or G2; on request with reducing nipple made of cast iron R1½ or R2 conical or cast steel G2 Measuring: precision to be specified: ... mm distance between 2 reed contacts (additional type designation): - 3.75 - 7.5 |
|
Working principle A float with built-in permanent magnet moves up and down with the liquid level on the probe tube of the TSQ 4-20/... liquid level indicator. Inside the probe tube, there is a chain made up of reed contacts and series-connected resistors. The magnet in the float switches the reed contact(s) which are at the same position as the float. This results in quasi-continuous height-proportional resistance measurement. The change in resistance resulting from the upward and downward motion of the float is recorded via a current loop transmitter in the terminal box of the TSQ 4-20/... liquid level indicator and converted into a load-independent current 4 ... 20 mA. Area of application The TSQ 4-20/... liquid level indicator is designed for use in low-viscosity liquids or liquids with only low solid content in open or closed tanks. It is not suitable for use in liquids that are prone to deposit formation, adhesion or crystallisation which might hinder the movement of the float on the probe tube. It is also not suitable for use in liquids with permanently moving surface and/or on vibrating machines. EMC: for interference emission in accordance with the appliance-specific requirements for households, business and commerce as well as small companies, and for interference immunity in accordance with the appliance-specific requirements for industrial companies.
|
|
| Measure drawing |
| Basic circuit |