Jola Spezialschalter K. Mattil & Co. KG
Klostergartenstraße 11-20
D-67466 Lambrecht
Phone: +49 63 25 / 188-01
 
Level controllers Leakage detectors Other Jola products Search via product names Control of the chemical resistance
General information on Jola Quality management system Addresses: Jola and its agents Help on CD-ROM catalogue
Float switch made of stainless steel

SM/E/3

  • installation of the float possible through hole accepting G1
    thread
  • Version with VDE marks licence

 
For applications up to max. AC 250 V

Only for use in liquids with a specific density >=1 g/cm³
Brochure Float switches SM [PDF]

Switching voltage AC min. 24 V
Switching voltage AC max. 250 V
Switching voltage DC min.  24 V
Switching voltage DC max.  250 V
Switching current AC min. 20 mA
Switching current AC max.  5,000 mA
Switching current AC max.
(inductive loads)
1,000 mA
Switching current DC min.  20 mA
Switching current DC max.  100 mA
Switching capacity AC max.  1,000 VA
Operating principle
microswitch: changeover contact
Float material stainless steel 316 Ti
Float form cylindrical float
Float diameter 28 mm
Float length 120 mm
Bellows material stainless steel 316 Ti
Screw-in nipple material stainless steel 316 Ti
Screw-in nipple dimension G1
Flange
On request: square blind flange with G1 thread 
made of steel St 37 or stainless steel 316 Ti
(dimensions see hyperlink below) or other flanges with 
any desired dimensions
Float protection class IP 68
Connection head
PP with M 20 x 1.5 cable entry, 
protection class IP 54
Mounting orientation horizontal
Mounting from the side
Temperature resistance
0° C to + 100° C
(inside the connection head: 0° C to + 60° C)
Pressure resistance
for pressureless applications 
(test pressure: max. 2 bar at + 20° C)

On request: connection head made of cast aluminium, protection class IP 54
This unit is not suitable for use in turbulent liquids (e.g. in stirrer tanks).

Mounting instruction:

This float switch must be mounted horizontally.
- screw the float switch with its seal into the G1 tank socket or flange borehole,
- seal in place,
- loose the two cheese head screws on the side – but do not remove –,
- set the connection head in such a way that the label “TOP” is at the top and the cable entry
  at the bottom,
- retighten the two cheese head screws.

 

Measure drawing
Option
Basic circuit
Top