Jola Spezialschalter K. Mattil
& Co. KG
Klostergartenstraße 11-20 D-67466 Lambrecht Phone: +49 63 25 / 188-01 |
Immersion probe with probe tube made of PVDF and float made of PVDF
TSR/3/PVDF/W
|
|
|
|
![]() |
|
For applications up to max. AC 250 V Float suitable for use in media with a specific density >=1 g/cm³ |
|
| Brochure Magnetically operated immersion probes TSR and TSM [PDF] | |
| |
|
| Switching voltage AC min. | 24 V |
| Switching voltage AC max. | 250 V |
| Switching voltage DC min. | 24 V |
| Switching voltage DC max. | 250 V |
| Switching current AC min. | 100 mA |
| Switching current AC max. | 2,000 mA |
| Switching current AC max. (inductive loads) | 400 mA |
| Switching capacity AC max. | 100 VA |
| Probe tube material | PVDF |
| Probe tube diameter max. | 16 mm |
| Probe tube length max. | 2,000 mm |
| Screw-in nippel material | PVDF |
| Screw-in nippel dimension | G1 |
| Flange |
Mounting accessories: square flange made of PVDF for immersion probes with G1 screw-in nipple. Counterflange on request. (See hyperlink below) |
| Float material | PVDF |
| Float diameter | 90 mm |
| Float length | 60 mm |
| Terminal box |
A 307 made of PP, 120 x 80 x 55 mm, protection class IP 65, for max. 12 terminals |
| Mounting orientation | vertical |
| Mounting | from the top |
| Temperature resistance |
Temperature application range taking into account the probe tube length: - max. 2,000 mm: from 0° C to + 40° C - max. 1,500 mm: from 0° C to + 45° C - max. 1,000 mm: from 0° C to + 55° C - max. 750 mm: from 0° C to + 70° C - max. 500 mm: from 0° C to + 80° C |
| Pressure resistance |
max. 2 bar at + 20° C |
| Contact |
reed contacts: make (NO), break (NC) or changeover (OC) contact |
| Max. number of contacts | 6 |
|
Min. distances to be observed |
80 mm |
| between contacts | 80 mm |
| from the lower contact to
the end of the probe tube (when float is falling) |
75 mm |
| Questionnaire | Questionnaire for inquiries or orders [PDF] |
| |
|
Probe tube on request, with inner tube made of metal to strengthen the probe tube made of plastic; max. number of contacts: 3 Probe tube length: according to customer's specifications, however max. 2,000 mm, taking into account the max. temperature in the tank and possible liquid turbulence Screw-in nipple: on request G2 Other terminal boxes and with free connecting cable in place of terminal box on request |
|
The above equipment will be manufactured in accordance with customer's specifications
|
|
| Measure drawing |
| Option |
| Top |