Jola Spezialschalter K. Mattil
& Co. KG
Klostergartenstraße 11-20 D-67466 Lambrecht Phone: +49 63 25 / 188-01 |
Float switch made of stainless steel
SMG/VE/S1
|
|
|
|
![]() | |
| Picture 2 | |
For light current applications Only for use in liquids with a specific density >=1 g/cm³ |
|
| Brochure Float switches SM [PDF] | |
| |
|
| Switching voltage AC min. | 1 V |
| Switching voltage AC max. | 42 V |
| Switching voltage DC min. | 1 V |
| Switching voltage DC max. | 42 V |
| Switching current AC min. | 0.1 mA |
| Switching current AC max. | 100 mA |
| Switching current AC max. (inductive loads) |
50 mA |
| Switching current DC min. | 0.1 mA |
| Switching current DC max. | 10 mA |
| Switching capacity AC max. | 4 VA |
| Operating principle |
microswitch: changeover contact |
| Float material | stainless steel 316 Ti |
| Float form | cylindrical float |
| Float diameter | 63 mm |
| Float length | 140 mm |
| Bellows material | stainless steel 316 Ti |
| Screw-in nipple material | stainless steel 316 Ti |
| Screw-in nipple dimension | G1 |
| Flange |
On request: square blind flange with G1 thread made of steel St 37 or stainless steel 316 Ti (dimensions see hyperlink below) or other flanges with any desired dimensions |
| Float protection class | IP 68 |
| Connection head |
PP with M 20 x 1.5 cable entry, protection class IP 54 |
| Mounting orientation | vertical |
| Mounting | from the top |
| Temperature resistance |
0° C to + 100° C (inside the connection head: 0° C to + 60° C) |
| Pressure resistance |
pressure resistance up to 4 bar at + 20° C / d >= 1.0 g/cm³ (test pressure: max. 6 bar at + 20° C) |
| |
|
On request: connection head made of cast aluminium, protection class IP 54 To protect the user and the contacts of our apparatus we recommend the use of our KR .. protection relays (see product group "Protection relays and alarm relays", click on heading "Others"). For full alarm, empty alarm or run dry protection: 1 relay per float switch For on/off control (with self-hold): 1 relay for 2 float switches |
|
This unit is not suitable for use in turbulent liquids (e.g. in stirrer tanks). Mounting instruction: These float switches must be mounted vertically. - remove the pin, - unscrew the float, - screw the float switch with its seal into the G1 tank socket or flange borehole, - seal in place, - screw back in place the float, - secure the float using the pin.
|
|
| Measure drawing |
| Option |
| Basic circuit |
| Top |