Jola Spezialschalter K. Mattil
& Co. KG
Klostergartenstraße 11-20 D-67466 Lambrecht Phone: +49 63 25 / 188-01 |
Level indicator with taps
HAM/E 32
|
|
|
|
![]() |
|
For applications up to max. AC 250 V Centre distance (see hyperlink below): as desired, up to max. 1,500 mm, special longer versions on request For liquid with a specific density >=0.95 g/cm³ |
|
| Brochure Magnetic switches, level indicators with taps and level controllers with magnetic switches [PDF] | |
| |
|
| Switching voltage AC min. | 1 V |
| Switching voltage AC max. | 42 V |
| Switching voltage DC min. | 1 V |
| Switching voltage DC max. | 42 V |
| Switching current AC min. | 0.1 mA |
| Switching current AC max. | 100 mA |
| Switching current AC max. (inductive loads) |
50 mA |
| Switching current DC min. | 0.1 mA |
| Switching current DC max. | 10 mA |
| Switching capacity | max. 4 VA or 0.4 W |
| Float material | PVDF |
| Float diameter | 26 mm |
| Float length | 150 mm |
| Flange |
Dimensions of the connecting flange: DN 32 PN 6 or DN 32 PN 10/16, other dimensions on request. |
| Mounted magnetic switches | HMW/1/32 |
| Contact |
changeover, bistable |
| Housing |
PP, approx. 65 x 50 x 35 mm Protection class: IP 65 Clamp material: PP, stainless steel on request Clamp diameter: for mounting of the magnetic switch on a pipe with an outside diameter of 30-32 mm; other tube clamp diameter available on request |
| Mounting orientation | vertical |
| Temperature resistance |
between + 1° C and + 60° C, other temperature application range on request |
| Pressure resistance |
for pressureless applications; pressure resistance on request |
| Valve material 1 | stainless steel 316 Ti |
| Valve material 2 | stainless steel 316 |
| Sightglass material | Duran |
| Outside diameter of the sightglass | 32 mm |
| Discharge port | 3/8" |
| Documents | Mounting instructions for the magnetic switches HMW/…[PDF] |
|
|
|
Sightglass material: transparent PVC on request Max. number of magnetic switches: as desired and according to the sightglass length |
|
This unit is not suitable for use on vibrating machines or in places at risk from shock or vibration.
|
|
| Measure drawing |
| Top |