Level controller
NEM 148
|
|
|
|
|
|
![]() |
|
For light current applications Guide tube dimensions: 28 mm dia. x the height based on the float rod length |
|
| Brochure Magnetic switches, level indicators with taps and level controllers with magnetic switches [PDF] | |
| |
|
| Switching voltage AC min. | 1 V |
| Switching voltage AC max. | 42 V |
| Switching voltage DC min. | 1 V |
| Switching voltage DC max. | 42 V |
| Switching current AC min. | 0.1 mA |
| Switching current AC max. | 100 mA |
| Switching current AC max. (inductive loads) |
50 mA |
| Switching current DC min. | 0.1 mA |
| Switching current DC max. | 10 mA |
| Switching capacity | max. 4 VA or 0.4 W |
| Float material | stainless steel 316 Ti |
| Float form | ball float |
| Float diameter | 148 mm |
| Float rod diameter | 6 mm |
| Float rod material | stainless steel 316 Ti |
Max. length of the float rod for |
1,200 mm |
| Screw-in nippel material | stainless steel 316 Ti |
| Screw-in nippel dimension | G1 |
| Flange |
Option: Installation flange for mounting of the unit from the outside: according to customer's specifications |
| Float rod bushing material | POM |
| Guide tube material | stainless steel 316 Ti |
| Guide tube diameter | 28 mm |
| Magnet capsule material | PP |
| Mounted magnetic switches | HMW/1/28 |
| Contact |
changeover, bistable |
| Housing |
PP, approx. 65 x 50 x 35 mm Protection class: IP 65 Clamp material: stainless steel Clamp diameter: for mounting of the magnetic switch on a pipe with an outside diameter of 28 mm; other tube clamp diameter available on request |
| Mounting orientation | vertical |
| Mounting | from the top |
| Temperature resistance |
between + 1° C and + 60° C, other temperature application range on request |
| Pressure resistance |
for pressureless applications |
| Documents | Mounting instructions for the magnetic switches HMW/…[PDF] |
|
|
|
Available float rod materials: - stainless steel 316 Ti or - titanium Float rod length: as desired, measured from the nipple sealing surface and without float (dimension L, see hyperlink below) Max. lengths with other specific gravities on request Float rod bushing material: on request PTFE Max. number of magnetic switches: as desired and according to the guide tube length Recommended application via Jola KR .. contact protection relay (see product group "Protection relays and alarm relays", click on heading "Others") |
|
This unit is not suitable for use in turbulent liquids ( e.g. in stirrer tanks) nor for use on vibrating machines or in places at risk from shock or vibration.
|
|
| Measure drawing |
| Top |