Magnetically operated float switches SMR/./E/..../C/A207

Schwimmerschalter SM
 

Technical data:

Model
SMR/3/E/..../C/A207
SMR/1/E/..../C/A207
Application
applications up to max. AC 250 V
for light current applications
Switching voltage
between
AC/DC 24 V and AC/DC 250 V
between
AC/DC 1 V and AC/DC 42 V
Switching current
between
AC 100 mA and AC 2 A (0,4 A)
between
AC 1 mA and AC 500 mA
Switching capacity
max. 100 VA
max. 20 VA
 

Types of the float switches SMR/./E/..../C/A207:

- SMR/./E/V/C/A207
= with square flange made of stainless steel 316 Ti


- SMR/./E/RDN65PN16/C/A207
= with round flange DN65PN16 made of stainless steel 316 Ti

- SMR/./E/RDN80PN16/C/A207
= with round flange DN80PN16 made of stainless steel 316 Ti

- SMR/./E/RDN100PN16/C/A207
=
with round flange DN100PN16 made of stainless steel 316 Ti


Magnetically operated float switches
SMR/E/..../Ex-0 II 2/1 GD EEx ia IIC T6

 
Schwimmerschalter SM
 

Technical data:

Model
SMR/E/..../Ex-0 II 2/1 GD EEx ia IIC T6
Application
For use in intrinsically safe circuits in potentially explosive atmospheres
- float side: Zone 0, 20, 1, 21, 2 or 22,
- terminal box: Zone 1, 21, 2 or 22.

EC type examination certificate: INERIS 03ATEX0223
 

Types of the float switches SMR/E/..../Ex-0 II 2/1 GD EEx ia IIC T6:

- SMR/E/V/Ex-0 II 2/1 GD EEx ia IIC T6
= with square flange made of stainless steel 316 Ti

- SMR/E/RDN65PN16/Ex-0 II 2/1 GD EEx ia IIC T6
= with round flange DN65PN16 made of stainless steel 316 Ti

- SMR/E/RDN80PN16/Ex-0 II 2/1 GD EEx ia IIC T6
= with round flange DN80PN16 made of stainless steel 316 Ti

- SMR/E/RDN100PN16/Ex-0 II 2/1 GD EEx ia IIC T6
= with round flange DN100PN16 made of stainless steel 316 Ti


 
These units are not suitable for use in turbulent liquids (e.g. in stirrer tanks).
 

 
These units must only be mounted and connected by a qualified specialist personnel.
 
Manufacturer reserves the right to alter the design and the technical data at his own discretion.
 
The details in this brochure are product specification descriptions and do not constitute assured properties in the legal sense.